Electrical ratings
Operating voltage, AC/DC suitability, frequency, short-circuit rating and protective-device coordination.
Compact busway with closely stacked, individually insulated copper conductors. Intended for main power distribution and high-density IT distribution with fixed tap-off points.
Explore available ratings and configuration options. Final specifications depend on your selected configuration.
| Busway family | Sandwich construction with insulated, stacked copper conductors |
|---|---|
| Catalog current range | 630-6300 A |
| Section groups detailed | 1000 / 1250 / 1600 A and 2000 / 2500 A |
| Standard section lengths | 1 / 1.5 / 2 / 3 m for the detailed section groups |
| Housing | Anodized aluminum-alloy enclosure |
| Tap-off positioning | Fixed connection points along the run |
| Branch configurations | High-current tap-off arrangements; final circuit schedule requires confirmation |
| Monitoring | Optional wired or wireless monitoring |
| Feed-in selection note | The catalog states 2000 A and 2500 A feed-in boxes do not include an incoming switch |
| Typical applications | Main distribution and high-density IT distribution |
Operating voltage, AC/DC suitability, frequency, short-circuit rating and protective-device coordination.
Dimensioned drawings, tap-off spacing, cable entries, support spacing, IP rating and environmental limits.
Selected-assembly certification evidence, test records, installation instructions and approved bill of materials.
Products are designed to meet applicable UL requirements, with certification arranged for the selected project configuration. Custom electrical ratings or design changes may require additional evaluation, testing or a new certification scope.
Planning timeline: approximately 3 months. This project estimate starts once the configuration, documentation and test samples are ready. Final scope, timing and certification are subject to UL review and successful testing.
Explore the equipment, components and assembly details.
A broad catalog family for main distribution and high-density IT loads. Select the complete assembly around the electrical design.
The 1000-1600 A and 2000-2500 A section groups list 1, 1.5, 2 and 3 m standard lengths. Confirm dimensions and ratings for each selection.
The catalog shows high-current tap-off arrangements and optional wired or wireless monitoring. Define branch protection and total loading for the selected unit.
Catalog family range only. Final voltage, frequency, fault rating, configuration and certification coverage require confirmation.