← All products
TRACK BUSWAY

Aperium Glide

100-1250 A | Catalog family range

Air-insulated track busway with a continuous access slot for tap-off placement along the run. A flexible distribution approach for IT equipment and evolving rack-row layouts.

Track busway and tap-off units
Technical selection

Specifications at a glance.

Explore available ratings and configuration options. Final specifications depend on your selected configuration.

Catalog specifications and configuration options
Busway familyAir-insulated track busway
Catalog current range100-1250 A
Housing groups100-400 A; 630 A; 800 A; 1000-1250 A
Tap-off positioningContinuous access slot along the bus run
Tap-off current examples63 A and 125 A three-phase; 250 A current class
Output arrangementsSingle- and three-phase options; cable-drop and receptacle variants
Monitoring pointsVoltage, current, power, energy, harmonics, temperature and switch status; module-dependent
CommunicationsNetwork / RS485 architecture shown; wired or wireless options
Feed-in optionsWith or without incoming switch and surge protection, according to configuration
Download technical summary · CSV ↓

Before you specify

Electrical ratings

Operating voltage, AC/DC suitability, frequency, short-circuit rating and protective-device coordination.

Mechanical & site

Dimensioned drawings, tap-off spacing, cable entries, support spacing, IP rating and environmental limits.

Documentation

Selected-assembly certification evidence, test records, installation instructions and approved bill of materials.

Designed for applicable UL requirements

Products are designed to meet applicable UL requirements, with certification arranged for the selected project configuration. Custom electrical ratings or design changes may require additional evaluation, testing or a new certification scope.

Planning timeline: approximately 3 months. This project estimate starts once the configuration, documentation and test samples are ready. Final scope, timing and certification are subject to UL review and successful testing.

Product & component details

See the hardware.

Explore the equipment, components and assembly details.

Track busway and tap-off units
Track busway and tap-off units
Track housing and conductor arrangement
Track housing and conductor arrangement
Tap-off enclosure and metering
Tap-off enclosure and metering
Product focus

Power where
the layout needs it.

01

Continuous access

Tap-off units connect along the continuous slot, allowing the connection layout to follow the rack arrangement.

02

Tap-off choices

Catalog options include 63 A and 125 A three-phase tap-offs and a 250 A current class. Output arrangements depend on the selected unit.

03

Electrical visibility

Monitoring options cover electrical measurements, temperature and switch status at the feed and tap-off units.

Application fit

Where this product fits.

Project requirements

Define the
configuration.

  • Bus current, voltage and available fault current
  • Rack layout and required tap-off locations
  • Outgoing circuits, connectors and protection
  • Monitoring points and communications interface

Catalog family range only. Final voltage, frequency, fault rating, configuration and certification coverage require confirmation.

Build your project brief ↗