← All products
FIXED TAP-OFF BUSWAY

Aperium Link

100-800 A | Catalog family range

Air-insulated busway with fixed tap-off positions along the run. Its low-profile arrangement suits IT distribution layouts where available installation height matters.

Fixed-position power distribution

Fixed tap-off points for planned rack layouts and space-constrained installations.

Technical selection

Specifications at a glance.

Explore available ratings and configuration options. Final specifications depend on your selected configuration.

Catalog specifications and configuration options
Busway familyAir-insulated, fixed tap-off busway
Catalog current range100-800 A
Tap-off positioningPredefined connection positions along the run
Installation focusHeight-constrained IT spaces and containerized IT modules
Feed-in current examples400 A and 800 A in the catalog selection code
Tap-off outputsOne, two or three output circuits
Protective-device polesOne-, two- or three-pole options
Branch-current examples16 A, 32 A and 63 A in the tap-off selection code
MonitoringOptional wired or wireless monitoring
Cable connectionCable-drop or connector-outlet variants
Feed-in optionsIncoming switch and surge protection options
Download technical summary · CSV ↓

Before you specify

Electrical ratings

Operating voltage, AC/DC suitability, frequency, short-circuit rating and protective-device coordination.

Mechanical & site

Dimensioned drawings, tap-off spacing, cable entries, support spacing, IP rating and environmental limits.

Documentation

Selected-assembly certification evidence, test records, installation instructions and approved bill of materials.

Designed for applicable UL requirements

Products are designed to meet applicable UL requirements, with certification arranged for the selected project configuration. Custom electrical ratings or design changes may require additional evaluation, testing or a new certification scope.

Planning timeline: approximately 3 months. This project estimate starts once the configuration, documentation and test samples are ready. Final scope, timing and certification are subject to UL review and successful testing.

Product & component details

See the hardware.

Explore the equipment, components and assembly details.

Fixed-position power distribution
Fixed-position power distribution
Feed-in and tap-off assembly
Feed-in and tap-off assembly
Tap-off enclosure detail
Tap-off enclosure detail
Product focus

Defined connections.
A compact power path.

01

Fixed connection points

Coordinate predefined tap-off positions with the rack plan and equipment connection layout.

02

Compact installation

Consider the low-profile arrangement for containerized IT spaces and other height-constrained installations; verify dimensions for the selected model.

03

Configurable outputs

Tap-off options include one, two or three output circuits and one-, two- or three-pole protective devices. Wired or wireless monitoring is optional.

Application fit

Where this product fits.

Project requirements

Define the
configuration.

  • Bus current, voltage and protection requirements
  • Available height and installation clearances
  • Tap-off spacing, circuit count and pole configuration
  • Cable exits, connectors and monitoring options

Catalog family range only. Final voltage, frequency, fault rating, configuration and certification coverage require confirmation.

Build your project brief ↗